151
Error Messages/Warning Messages/Condition Messages
App
end
ix
Only one message will be displayed even if there are
multiple messages. The number of errors appears at the
lower right, and you can check the messages using the
R
and
r
buttons.
A history of errors is kept in the error log menu.
For more information about warning messages, refer to
the Maintenance Manual.
Use the displayed warning information to eliminate the
cause of the warning.
For more information about eliminating the cause of
warning, refer to the Maintenance Manual.
To automatically display a warning message
Whenever a warning occurs, change the setting of the VTR
SETUP menu item 120 “WARNING DISPLAY” to “on”.
To clear a warning message
To cancel the display of a warning message, see “Clearing
warning messages” on page 154.
Item number
Display
Meaning
01
NO EXTERNAL REFERENCE
There is no reference signal on the selected REF. INPUT
connector. The VTR is using an internal reference signal.
02
LOST LOCK
Capstan servo lock was lost during playback, recording, or editing.
03
NO EXTERNAL REFERENCE ON
FC
When the VTR SETUP menu item A05 “PD EXT SD REF LOCK
MODE” is set to “lock1” or “lock2”, no external SD reference signal
is input.
04
HD & SD REF ASYNCHRONOUS
When the VTR SETUP menu item A05 “PD EXT SD REF LOCK
MODE” in is set to “lock1” or “lock2”, HD reference signal and
external SD reference signal are not synchronized.
05
PLL UNLOCK ON FC
The PLL of the HKSR-5001 is not locked on the reference signal.
06
SDI A-B PHASE NG
The signals to the HD SDI INPUT A/B connectors are out of phase
with each other.
08
NO SDI INPUT
An SDI input signal cannot be detected.
10
VITC NOT READ
VITC cannot be correctly read from the tape.
11
AUDIO PLL UNLOCKED
Audio lock generator PLL not locked to the video reference signal.
14
NO PB RF SIGNAL
Playback heads cannot correctly read digital data from the tape.
15
INCONSISTENT EMPHASIS
Emphasis information on the tape is inconsistent with the system
emphasis status.
16
INCONSISTENT FORMAT
The meta data being input and the meta data recorded on the tape
have different formats.
17
PB FREQUENCY IS UNSUITABLE
The cassette is ejected automatically in line with the setting of the
VTR SETUP menu item 018 “AUTO EJECT LEVEL” because the
system frequency of the VTR and the frequency of the signal
recorded on the tape do not match.
18
INCONSISTENT AUDIO
FREQUENCY
Sampling frequency information for playing back the tape and
sampling frequency information on the system do not match for
certain channel(s).
19
NO A1/A2 INPUT
No carrier detected on digital audio input on channels 1 and 2
Warning message
I N S
A U D I O
H O M E
R E M A I N : - - H - - M
H D C A M - S R
S T A N D B Y O F F
Warning mark