1-36 (E)
.
IM/HDCU1000 Series
2.
When the turn stops, pull out the remover in the
straight line forcedly.
n
The alignment sleeve can be removed/reinstalled with
the sleeve itself attached to the tip of the remover.
Great care should be taken so as not to lose or damage
the alignment sleeve.
(Alignment sleeve: Sony P/N 9-980-074-01)
3.
Clean the tip of the white optical contacts by a cotton
swab moistened with alcohol.
4.
Insert the remover with the alignment sleeve attached
to its tip, and push it until it clicks.
5.
Rotate the remover counterclockwise to install the
alignment sleeve, and extract the remover.
1-12. Cleaning of Connector/Cable
Before connecting the unit to the camera, it is recommend-
ed to clean the following optical contact portions.
.
CAMERA connector of the unit
.
CCU connector of the camera side
.
Optical/electrical cable
Cleaning of the Standard Connector/Cable
Clean the standard connector/cable (manufactured by
LEMO) in the following steps.
Tools Required
.
Alignment sleeve remover HC-001
(for female connector)
Sony P/N : J-6480-010-A or
DCC.91.312.5LA manufactured by Lemo, or equivalent
n
Insert the shorter nose end when removing/installing the
alignment sleeve.
Grasp not the shock absorber portion of the remover but
the handle in use.
.
Alcohol
.
Cotton swabs (commercially available)
n
Use a cotton swab whose diameter is about 4 mm.
If a cotton swab whose diameter exceeds 5 mm is used,
the cotton swab cannot be inserted into the end of the
connector and the tip of the optical contact cannot be
cleaned.
Use the shorter nose end.
Shock absorber
Handle
[Female connector]
The optical contacts for female connector are in an unex-
posed state. In cleaning, it is necessary to be exposed by
removing the alignment sleeve in advance. Proceed as
follows.
1.
Insert the alignment sleeve remover into the alignment
sleeve in the straight line and turn it clockwise.
Cleaning
[Male connector]
Clean the tip of the white optical contacts by a cotton swab
moistened with alcohol.
Optical contacts (white)
Alignment sleeve
Alignment sleeve remover
Alignment sleeve
Optical contacts (white)