IM/HDCU1000 Series
1-19 (E)
A
B
C
D
E
F
G
H
J
1
2
3
4
5
D104
S4
S2
S3
D105
S1
D106
D109
RV600
RV601
S603
S602
S600
S601
RV501
RV500
S501
S500
S503
S502
S12 S11
S22
S32
S21
S31
AVP-6 (Side A)
AVP
/1.001
LINE
DELAY
CCU
POWER
CAM
LOCK
CAM POWER
SYSTEM
ON/
OFF
PROD
ENG
2WIRE CANCEL
AVP-6 board
Ref.No. Name
Function
Factory default setting
D104
CCU POWER
(Green) Illuminates when the power to the boards in the whole CCU is
_
functioning properly.
D105
CAM LOCK
(Green) Illuminates when the communication with camera head is normal.
_
D106
/1001
(Green) Illuminates when the operation clock frequency of SG is 74.17582 MHz.
_
(When the frame frequency of the video signal is integer 1/1.001.)
D107
90H
(Yellow) Illuminates when the SD signal delay time at down-conversion is set to
_
(LINE DELAY)
LINE-DELAY.
_
S1
CAM POWER
Toggle switch that turns on the power to the camera head when it is off, and turns
off when it is on.
S2
Not used
0
S3
Not used
0
S4
MODE 1-7
Factory use
OFF (ALL)
8
Set this to ON when upgrading the PLD (IC208, IC409) version of the SDP-12
OFF
board. (Be sure to set the switch to OFF after the upgrade is completed.)
S11
R-TALLY
Set according to the signal standard of the R-TALLY signal input to the INTERCOM/
CONTACT
(POWER/CONTACT)
TALLY/PGM connector on the rear panel. For the relationship between the signal
S12
R-TALLY
and the switch setting, refer to the table below.
TTL
(POWER/TTL)
S21
G-TALLY
Set according to the signal standard of the G-TALLY signal input to the INTERCOM/
CONTACT
(POWER/CONTACT)
TALLY/PGM connector on the rear panel. For the relationship between the signal
S22
G-TALLY
and the switch setting, refer to the table below.
TTL
(POWER/TTL)
S31
U-TALLY
Not used
CONTACT
(POWER/CONTACT)
Tally system setting
Red tally
Green tally
Switch
S11
S12
S21
S22
Signal standard
POWER/
POWER/TTL
POWER/
POWER/TTL
CONTACT
CONTACT
Contact supply
CONTACT
_
CONTACT
_
24 V power supply
POWER
POWER
POWER
POWER
5 V power supply
POWER
TTL
POWER
TTL