1-16 (E)
.
IM/HDCU1000 Series
Ref.No. Name
Function
Factory default setting
S412
SYNC
Sets the SYNC signal output from the SYNC terminal to HD or SD.
SD
HD : HD-SYNC signal output
SD : SD-SYNC signal output
S413
Factory use
OFF
S416
Co-AX/D-S-F1
Not used
Fiber
S418
48V/50V/60V
Multi-Format setting (Camera transmission format)
60
When the operation clock frequency setting switch (S420) is set to Local, the main
video format of CCU is set as in the following table. The output transmission format
of CHU is also set in the same way. (Refer to the table below.)
S419
720/Psf/I
Multi-Format setting (Camera transmission format)
INTR
When the operation clock frequency setting switch (S420) is set to Local, the main
video format of CCU is set as in the following table. The output transmission format
of CHU is set in the same way. (Refer to the table below.)
S420
1001/RMT/1000
Operation clock frequency setting
REMOTE
1.001 : Sets the field frequency of CCU to 59.94, 29.97, 23.98 Hz.
1.000 : Sets the field frequency of CCU to 60, 50, 25, 24 Hz.
REMOTE : Can be set from MSU.
*
Can also perform remote/local setting of video output format from CCU.
RV701
27M FREQ
Volume that adjusts the free-run frequency of 27M-VCO (X701). Must be
readjusted when replacing X701.
RV702
CK-DUTY
Volume that adjusts the clock duty of the 74 MHz clock.
FORMAT
S420
S418
S419
1080-60 (or 59.94) i
1.000 (or 1.001)
60 V
Intr
1080-30 (or 29.97) PsF
1.000 (or 1.001)
60 V
PsF
1080-50 i
1.000
50 V
Intr
1080-25 PsF
1.000
50 V
PsF
1080-24 (or 23.98) PsF
1.000 (or 1.001)
48 V
PsF
720-60 (or 59.94) P
1.000 (or 1.001)
60 V
720 P
720-50 P
1.000
50 V
720 P