CSM-200
6-9
Parallel (D-sub 9pin)
1(5)
5
(1)
9
(6)
6 (9)
6-4. Input/Output Signals of the Connector
Harness (CB-UPS) (CB-121 board and connection)
Parallel (D-sub 9-pin, Male)
CSM-200BF Serial No. 1001081 to 1001098
CSM-200BF Serial No. 1000001 to 1000004
Parallel (D-sub 9-pin, Female) models other than the above
Pin No.
Signal
Contents
1
N.C.
—
2
BYPASS IN
*
1
Bypass mode : SHORT
(Battery non-charge mode)
Inverter mode : OPEN
(Battery charge mode)
3
AC LEVEL FAIL IN
*
1
When the commercial
AC power input is abnormal : SHORT
When the commercial
AC power input is normal :
OPEN
4
RELAY COM
Common GND
5
LOW BATTERY IN
*
1
Low battery :
SHORT
Enough battery : OPEN
6
UPS OFF IN
*
2
When UPS is not available : OPEN
When UPS is available :
SHORT
7
N.C.
—
8
N.C.
—
9
N.C.
—
*
1 : When the corresponded signal line does not exist at the UPS side, leave it to N.C. (Not Connected).
*
2 : When the corresponded signal line does not exist at the UPS side, short 6-pin with 4-pin.
n
When the UPS connector is short-circuited between the input port and RELAY COM, this connector
passes a current of maximum
+
11 mA via the UPS. The 2.1 s-wide or less signal is not transmitted.
Numbers in ( ) are for male pins.