CSM-200
4-24
M4
x
8
Casters
Casters
Spacers (portion B)
Spacers (portion C)
Reference pin
9.
If the accumulated difference between [A]-[A] at both of the upper side (L1) and the lower side (L2)
of the X-reference pin exceeds 2 mm, take the following measures.
(1) Remove the eight hexagonal head bolts and the two flat cables of the extension console at the
point where the accumulated difference exceeds 2 mm.
(Do not move the consoles horizontally while adjustment is in progress.)
(2)
.
If the accumulated difference at the upper side is smaller than that of lower side, rotate the two
casters that are located at the far side from the Basic storage system in counter-clockwise
direction by 30
d
, and insert spacers that are supplied with CSMA-CBLS/CBLL, in the portions
B (there are two portions B in the front and rear). Then tighten the eight hexagonal head bolts
that are removed in step (1).
.
If the accumulated difference at the lower side is smaller than that of upper side, rotate the two
casters that are supplied with CSMA-CBLS/CBLL, that are located at the far side from the
Basic storage system in clockwise direction by 30
d
, and insert spacers in the portions C (there
are two portions C in the front and rear). Then tighten the eight hexagonal head bolts that are
removed in step (1).
(3) Connect the two flat cables that are removed in step (1).
10. Attach all of the blank panels (1U) of the extension console that are removed in step 4.