4-117
CSM-200
Bin ASSY
PWH4
x
8
PWH4
x
8
Blank panel
(drive)
Extending the Drive Area (Basic storage system)
When the basic storage system is shipped from the factory, the single row is assigned to the drive area,
and the two rows are assigned to the bin areas. The bin areas can be changed to the drive areas as
described below.
n
When you want to change the bin areas to the drive areas, change the area starting from the lower row.
Changing procedure
This section describes the procedure to change the lower row of the bin area to the drive area as follows.
You can change the upper row of the bin area to the drive area following the same steps.
There are two types of drive reflector plate base, that are different with respect to the mounting method,
and are shipped in different shipment time.
The steps (4) to (7) of the changing procedure below are different depending on the types. Identify the
plate base type by shape and implement the correct procedure.
(1) Open the front door, rear door and bin door. (Refer to “4-2-1. Opening the Outer Cabinets”.)
(2) Remove the four screws and remove the BIN ASSY.
(3) Remove all of the blank panels (drive) from the row that you want to change from the bin area to the
drive area.
n
Store the removed blank panels (drive) and screws in a safe place so that they will not be lost.