CSM-200
4-28
(8) Tighten the hexagon head cap bolt (c) of the connecting block of the extension console side.
(9) Tighten the hexagon head cap bolt (a) (of the extension console side) that was provisionally
tightened in step (4).
(10) Tighten the nut securing the hexagon head cap bolt (c) so that the bolt will not become loose.
(11) Tighten the hexagon head cap bolt (d) so that the X rail (top) contacts the reference pin.
(12) Tighten the five hexagon head cap bolts (b).
(13) Tighten the nut securing the hexagon head cap bolt (d) so that the bolt will not become loose.
(14) Tighten the two hexagon head cap bolts (e).
(15) If you are expanding second and subsequent extension consoles, connect the X rails (top) in the
same procedure as described above. Even if you do not expand second and subsequent extension
consoles, tighten the nut securing the hexagon head cap bolt (f) so that the bolt will not become
loose.
(b) M4
x
14
(b) M4
x
14
(e) M4
x
25
(c) M4
x
16
(a) M4
x
14
(d) M4
x
12
(f) M4
x
16
X rail (top)
Rail (T) holer
Connecting block
Nut
Nut
Reference pin
Содержание CSM-100BF
Страница 4: ......
Страница 8: ......
Страница 10: ......
Страница 18: ......
Страница 24: ...CSM 200 4 6 Rear door 2 Open the rear door ...
Страница 150: ......