3-12
FVS-1000 MMP1
PSW3
x
6
B3
x
12
B3
x
6
Lamp base stay (L)
Fan plate
Heat sink
FLC fan entrance
Bottom view
Cleaning
FLC fans
FLC Fan Entrance and Heat Sink
(1) Remove the three screws, and remove the lamp base
stay (L).
(2) Remove the two screws, and remove the fan plate.
(3) Vacuum the dusts on the heat sink using a vacuum
cleaner, etc.
(4) Vacuum the dusts on the fan entrance using a vacuum
cleaner, etc.
(5) Wipe off the dirt on the fan entrance and heat sink
using a dry cloth.
Lamp Exit and Heat Sink
(1) Vacuum the dusts on the lamp exit and heat sink using
a vacuum cleaner, etc.
(2) Wipe off the dirt on the lamp exit and heat sink using a
dry cloth.
Lamp
Lamp exit
Heat sink
3-3. Cleaning the Optical System