2-11
FVS-1000 MMP1
2-3. Location of Main Parts
No.
Sensor
Function
1
Front internal lock SW
The power is turned on by closing the front door.
2
S side tension regulator potential meter
This meter detects the rotation angle of the S side tension regulator arm.
3
S tension regulator position sensor
This sensor detects load and unload position of S tension regulator.
4
S side reel A/B winding SW
This switches A/B winding at the S side reel.
5
Lens emergency
This detects the lens position. (Photo-diode)
6
Gate (retainer) discrimination SW
This switch discriminates between 16 mm and 35 mm of the gate.
7
S side PAD roller position sensor
This sensor detects load and unload position of the S side PAD roller.
8
S side PT roller position sensor
This sensor detects load and unload position of the S side PT roller.
9
A side PAD TYPE SW
This switch discriminates between 16 mm and 35 mm of the S side PAD roller and
detects whether the S side PAD roller is installed or not.
!/
Electrostatic sensor
This sensor detects the film (perforations) position.
!-
Gate TYPE SW
This switch discriminates between 16 mm and 35 mm of the gate and detects whether
the gate is installed or not.
!=
Slide adaptor detection SW
This switch detects the slide adaptor.
![
Mirror
!]
Gate position sensor
This sensor detects the load and unload position of the gate (retainer).
!\
T side tension regulator potential meter
This meter detects the rotation angle of the T side tension regulator arm.
!;
T side tension regulator position sensor
This sensor detects the load and unload position of the T side tension regulator.
!'
T side reel A/B winding SW
This switches A/B winding at the T side reel.
!,
Lens emergency (LED)
This detects the lens position.
!.
OPS H direction glass sensor
This sensor detects the glass position in the horizontal direction of the OPS.
@/
OPS V direction glass sensor
This sensor detects the glass position in the vertical direction of the OPS.
@-
T side PAD roller position sensor
This sensor detects load and unload position of the T side PAD roller.
@=
T side PT roller position sensor
This sensor detects load and unload position of the T side PT roller.
@[
T side PAD TYPE SW
This switch discriminates between 16 mm and 35 mm of the T side PAD roller and
detects whether the S side PAD roller is installed or not.
@]
Integral ball discrimination sensor
This sensor discriminates among 16 mm, 35 mm and 8P of the integral ball.
@\
Lamp SW
Emergency switch to turn off the lamp
@;
STANDBY SW
Switch for STANDBY
@'
SV RESET SW
Switch for servo reset
@,
Breaker
Switch to turn on or off the system
@.
Rear internal lock SW
When replacing the lens, the power is turned off by opening the rear door.
#/
Lens load SW
When replacing the lens, the lens can be moved.
#-
Imager movement table position sensor
This sensor detects whether the imager movement table is pulled out or not.
#=
Loop sensor
For detecting the loop amount between the sprockets.
Rear side
#/
@.
#-
Содержание BKFV-100/1
Страница 4: ......
Страница 10: ......
Страница 68: ......
Страница 72: ...2 4 FVS 1000 MMP1 1 1 1 1 1 7 6 8 9 1 1 5 4 2 3 Rear side 2 3 Location of Main Parts FVS T1000 Rear panel ...
Страница 78: ...2 10 FVS 1000 MMP1 4 5 6 8 8 9 7 3 2 1 Front side 2 3 4 Location of Sensors 2 3 Location of Main Parts ...
Страница 130: ......
Страница 194: ......
Страница 202: ......
Страница 248: ...7 4 FVS 1000 MMP1 O A 8321 649 E FILTER ASSY BOX S 1 758 295 11 IR UV CUT FILTER S 1 517 872 11 LAMP WITH PLASTIC CASE ...
Страница 250: ......
Страница 256: ......
Страница 258: ...Printed in Japan Sony Corporation 2001 12 08 B P Company 1999 FVS T1000 UC FVS P1000 SY E 3 202 167 04 ...