PAT-80
● PAT-85 ● PAT-86 – USER MANUAL
7
Measurement of differential leakage current
adjustable measurement time
adjustable upper limit in the range of: 0.01 mA ... 9.9 mA with 0.01 mA / 0.1 mA resolution
measurement of the current with clamp
Measurement of touch leakage current
adjustable measurement time
adjustable upper limit in the range of: 0.01 mA ... 1.99 mA with 0.01 mA / 0.1 mA resolution
Measurement of welding machine parameters
primary circuit leakage current I
P
welding circuit leakage current I
L
U
RMS
voltage
U
P
voltage (DC and AC
peak
)
Measurement of power P, Q and S
adjustable measurement time
measurement of power factor PF
measurement of cos
φ
measurement of THD of voltage and current
Measurement of current consumption
Measurement with the device's internal measurement circuits or with clamp
Measurement of RCD / PRCD parameters
time-delayed and general
I
Δn
= 10 mA, 15 mA, 30 mA
measurement of I
A
current and RCD tripping time t
A
for 0.5 I
Δn
, 1 I
Δn
, 2 I
Δn
, 5 I
Δn
Visual test
IEC cord test
Furthermore:
automatic selection of measuring range
tree structure of measurement results memory with provision of printing or transferring the re-
sults to PC via USB link
configurable with a QR-code scanner and printer
power supply sustained for ca. 1 hour after disconnecting mains power supply with the use of
built-in battery
ergonomic operation