PAT-80
● PAT-85 ● PAT-86 – USER MANUAL
61
5.2
Measurement of leakage current I
P
in welding machines
Press
I
P
.
Before starting the measurement, similarly to
sec.
, following parameters must be set:
test dura-
tion, limit, polarity
and
test method
.
In
Change polarity
select:
Yes
if the measurement is
to be repeated for reverse
polarity,
No
if the measurement is
performed for only one po-
larity.
In
Test method
select:
Socket
, if test socket is to
be used for the measure-
ment,
Adapter
, if test PAT-3F-PE
adapter is to be used for
the measurement.
Measurement with test socket
Connect the mains plug of the tested appliance into the test socket of the tester. The T1 cable
can be connected but does not have to be.