464
EGO Smart Heater
1
EGO Smart Heater
1.1
EGO Smart Heater (RS485)
Termination
Addressing
Interface
Yes
No
RS485
Overview
•
Integrated interface.
•
Where to connect: Terminal strip inside the heating rod.
•
3-pin wiring.
•
The communication address does not have to be assigned.
•
Installation steps:
•
Switch off the heating rod and Solar-Log™.
•
Connect the heating rod to the Solar-Log™.
Connect the EGO Smart Heater
to the Solar-Log™:
The wiring is done using a
•
self-made, shielded 3-wire data cable and terminal block connector.
General information on managing and prioritizing the EGO Smart Heater via smart energy
The Solar-Log™ can manage and prioritize up to six EGO Smart Heaters with the smart energy function.
The connection of the Smart Heaters can be made in different ways.
Two examples should clearly illustrate the options:
Example 1
Six heating rods are connected via the Ethernet option; it is not possible to connect any additional heating rods via
the RS485 interface.
Example 2
One heating rod is connected per interface via the RS485 A and RS485/422 B interface. This allows four heating
rods to be connected via Ethernet.
Note
Only one EGO Smart Heating can be operated per RS485 interface.
Содержание Solar-Log
Страница 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Страница 20: ...20 01 Inverter ...
Страница 366: ...366 Surpass SSE Note Feed in management Power reductions of less than 10 are set by the inverters to 10 ...
Страница 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Страница 402: ...402 02 Meter ...
Страница 444: ...444 03 Battery Systems ...
Страница 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Страница 463: ...463 04 Heating rods ...
Страница 470: ...470 05 Heating pumps ...
Страница 478: ...478 06 Sensors ...
Страница 488: ...488 07 Pyranometer ...
Страница 495: ...495 08 Smart Plug components ...
Страница 502: ...502 09 Power Charging Stations ...