317
SolarEdge
Procedure
1. Open the inverter as shown in the inverter's instructions.
2. Pull the free wires through the wire opening in the inverter.
3. If you are making the cable yourself, connect the wires as shown in the following diagram:
Solar-Log™ terminal strip connector
X4 socket RS485-1 inverter
Terminal
PIN
►
1
A - Data+
►
3
G - GND
►
4
B - Data-
4. If no further inverter connected, terminate the inverter with DIP switch SW7 according to the manufacturer's
instructions.
5. Screw the inverter cover on again.
6. Insert the terminal block connector into the Solar-Log™ RS485 socket.
Connect the inverters to each other
•
Where to connect: Terminal strip inside the inverter
Procedure
1. Open the inverter as shown in the inverter's instructions.
2. Pull the free wires through the wire opening in the inverter.
3. If you are making the cable yourself, connect the wires as shown in the following diagram:
X4 socket RS485-1 inverter n
X4 socket RS485-1 inverter n+1
PIN
PIN
A - Data+
A - Data+
G - GND
G - GND
B - Data-
B - Data-
4. Connect the other inverters to each other in the same way.
5. Terminate the last inverter with DIP switch SW7 according to the manufacturer's instructions.
6. Screw the inverter cover on again.
7. Insert the terminal block connector into the Solar-Log™ RS485 socket.
Allocate communication address
•
Recommendation: Continuous numbering starting with 1; highest possible address: 247.
•
Setting: Using the inverter operating display
•
Procedure: Start according to the inverter's instructions
Inverter settings
Two settings need to be checked on the inverter's control panel and changed if needed before performing the
inverter detection.
1.
Non-SE Logger
has to be set in the
Communication // RS485-1 Conf // Device Type
menu.
2.
SunSpec
has to be activated in the
Communication // RS485-1 Conf // Protocol
menu.
Содержание Solar-Log
Страница 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Страница 20: ...20 01 Inverter ...
Страница 366: ...366 Surpass SSE Note Feed in management Power reductions of less than 10 are set by the inverters to 10 ...
Страница 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Страница 402: ...402 02 Meter ...
Страница 444: ...444 03 Battery Systems ...
Страница 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Страница 463: ...463 04 Heating rods ...
Страница 470: ...470 05 Heating pumps ...
Страница 478: ...478 06 Sensors ...
Страница 488: ...488 07 Pyranometer ...
Страница 495: ...495 08 Smart Plug components ...
Страница 502: ...502 09 Power Charging Stations ...