412
Solar-Log™ PRO
Cable connection via S0 (in):
Solar-Log™ S
0
terminal block
Solar-Log™ PRO1-Mod
Pin assignment
Pin assignment
1 - S0+
20 - S0+
2 - S0-
21 - S0-
3
4
Place a cable bridge between pin 3 and 4 on the Solar-Log™.
Possible meter operating modes for the Solar-Log™ PRO1 Mod via SO connection:
•
Total plant meter
•
Sub-consumption meter
•
Consumption meter
•
Generator
Meter‘s impulse factor:
1000 p / kWh
Note the SO pulse length for the Solar-Log™ PRO1-Mod.
The following values for the SO pulse length are known:
►
≤
5625W = pulse length 32ms
►
> 5625W = pulse length 11,2ms
The Solar-Log™ can process a SO pulse with at least a length of 30 ms. This means a maximum pulse
length of 5625W can be defined for the S0 output of the Solar-Log™ PRO1 Mod.