105
Effekta
Procedure
1. If you are fabricating the cable yourself, connect the wires as shown in the following diagram:
Solar-Log™ terminal strip connector
RS485 inverter socket
Terminal
PIN
►
1 A/Data +
►
Pin 1 (A) T/R+
►
3 GND
►
Pin 5 GND
►
4 B/Data -
►
Pin 2 (B) T/R-
2. Insert the RJ45 plug into the RJ45 socket on the inverter.
3. If no further inverter connected, terminate the inverter:
Set the dip switch to “on.”
4. Insert the terminal block connector into the Solar-Log™ RS485 socket.
Connect the inverters to each other
•
Connect using a network cable (patch cable) (
No
Crossover cable).
•
Where to connect: RJ45 sockets on the outside of the inverter.
Procedure
1. Insert the RJ45 plug into the free RJ45 socket on the first inverter.
2. Insert the other end of the wire into any RJ45 socket on inverter 2.
3. Connect the other inverters to each other in the same way.
4. Terminate the last inverter, set the DIP switch to “on.”
Allocate communication address
•
Recommendation: Continuous numbering from 1 to 32.
•
Setting: Using the inverter operating display.
•
Procedure: Start according to the inverter’s instructions.
Note
The following setting needs to be enable so that the PM parameters can be received.
SETUP
►
REMOTE CNTRL
►
ENABLE
Содержание Solar-Log
Страница 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Страница 20: ...20 01 Inverter ...
Страница 366: ...366 Surpass SSE Note Feed in management Power reductions of less than 10 are set by the inverters to 10 ...
Страница 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Страница 402: ...402 02 Meter ...
Страница 444: ...444 03 Battery Systems ...
Страница 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Страница 463: ...463 04 Heating rods ...
Страница 470: ...470 05 Heating pumps ...
Страница 478: ...478 06 Sensors ...
Страница 488: ...488 07 Pyranometer ...
Страница 495: ...495 08 Smart Plug components ...
Страница 502: ...502 09 Power Charging Stations ...