-89-
No. JXC
※
-OMT0002-C
Name of the
controller
setting
software
(code)
G
roup
How to
deactivate
Alarms and countermeasures
Return to
ORIG did not
complete in the
set time.
(1-097)
C
RESET
is ON
< Details >
Return to origin was not completed within the set time.
<Countermeasure>
- If the ORIG mode is "0: Pushing Return to origin", the controller
parameter “model” and the actual actuator model may not match. Check
the parameters. Also, the motor shaft may be loose. Please refer to the
actuator operation manual.
- If the ORIG mode is "2, 3: Return to origin with sensor", check that the
sensor mounting and the cable connection of the sensor are correct.
DRIVE is ON
when SVRE is
OFF (1-098)
C
RESET
is ON
< Details >
An alarm is generated when a Return to origininstruction is made when
the servo is OFF.
<Countermeasure>
Start the operation when the servo motor is ON (SVRE is ON).