-53-
No. JXC
※
-OMT0002-C
Description
Input range
Explanation
Position
“Stroke (-)” to “Stroke
(+)” in the basic
parameters
Set the target position (Unit: mm)
Refer to (1) to (5) on page 53 for position setting for movement mode.
Acceleration
1 to “Max ACC/DEC” in
the basic parameters
Set the acceleration to reach to travel speed. (Unit
:
mm/s
2
)
Refer to (1) to (5) on page 53 for acceleration speed setting for movement
mode.
Deceleration
1 to “Max ACC/DEC” in
the basic parameters
Set the deceleration from travel speed to stop. (Unit
:
mm/s
2
)
Refer to (1) to (5) on page 53 for deceleration speed setting for movement
mode.
Pushing Selection
0 or 1
Define a Pushing operation or Positioning operation.
When a Pushing operation is selected, it is performed at a force greater
than the pushing force set in the profile parameters.
Value
Movement
mode
Details
0
Positioning
operation
The actuator moves to the position
specified by the “Position".
1
Pushing
operation
The actuator moves to the position
specified by the “Position”, and then
performs a pushing action with a force not
greater than the set force.
Area 1
“Step data "Area 2"
from "Stroke (-
)” in the
basic parameters
The setting to define the conditions where the AREA will be turned ON
(Unit: mm)
If the current position is within the range between the Area1 and Area2,
the AREA will be turned ON.
If Area1= Area2= 0, the AREA will be turned OFF.
Area 2
Step data "Area 1" to
")” in the basic
parameters
In-position
Note1)
The In-position functionis different for the pushing operation and the
positioning operation.
●Positioning operation: Positioning range (Unit: mm)
●Pushing operation: Pushing range (Unit: mm)
Movement
mode
Details
Positioning
operation
This setting defines the In-position, where the INP will
be turned ON.
When the actuator moves to within a distance from the
target position, the INP will be turned ON.
Pushing
operation
This setting defines the distance pushed by the
actuator during the pushing operation.
The INP will be turned ON when the pushing force
exceeds the "Trigger level" set in the profile
parameters.
Note1) The range varies depending on the actuator. Refer to the actuator operation manual for more
details.