-66-
No. JXC
※
-OMT0002-C
(1) Select Step No.1. (Turn IN0 ON.)
↓
(2) Turn the DRIVE ON.
↓
The Motor starts to move to the position set in Step No.1.
↓
(3)Step No.1 is turned ON.
(OUT0 is turned ON)
↓
(4)INP is turned OFF.
↓
(5)BUSY is turned ON.
↓
(6)Turn the DRIVE OFF.
↓
(7)INP is turned ON.
↓
(8)BUSY is turned OFF.
↓
The move to the position set in Step Data No.1 is
completed.
↓
(9)Select Step No.2.(Turn the IN0 OFF, and the IN1 ON.)
↓
(10)Turn the "DRIVE" ON.
↓
Start moving to a point at 100mm on Axis 1 and 50mm on
Axis 2.
↓
(11)Step No.2 is turned ON.
(OUT1 is turned ON)
↓
(12) INP is turned OFF.
↓
(13) BUSY is turned ON.
↓
(14) DRIVE is turned OFF.
↓
(15) INP is turned ON.
↓
(16) BUSY is turned OFF.
↓
Move to a point at 100mm on Axis 1 and 50mm on Axis 2.
Flow chart (Reference)
P
L
C
(2)(6)(10)(14)
(15), (12), (7), (4)
(16), (13), (8), (5)
(11)
(3)
」
(9)
(1)
Controller
Signal name
DRIVE
IN0
IN1
OUT0
OUT1
INP
BUSY