-76-
No. JXC
※
-OMT0002-C
(3) Pushing operation
- Procedure -
- Timing chart -
(a) Output the step data No.
(INx).
↓
(b) Turn the DRIVE ON.
The step data No.
(OUTx) will be input.
↓
(c) The BUSY turns ON
and INP turns OFF.
(Pushing starts).
↓
(d) The pushing operation
is complete when INP
is ON and BUSY is
OFF. (The force set as
the "Pushing Force" in
the profile parameter will be generated).
Caution
1) If the movement is interrupted during positioning of the pushing operation, an alarm
“(0-149) Failed
to achieve set position in set time limit
”will be generated.
2) If an operation is instructed after the pushing operation is completed ((d) above), a positional offset
will be generated.
Correct the offset by performing the ABS instruction twice or more.
Power supply
In
p
u
t
Ou
tp
u
t
External lock
The INP will turn ON when a force greater than "Trigger
level" set in the profile parameter is generated.
The BUSY signal turns OFF after the pushing completion
time (theoretical value) has lapsed.
Pushing operation
Current step data No.
Previous step data No.
Min.15ms
Unlock
Helding
Speed