99-00850-21 B0
Maintaining Your 600i2 Interactive Whiteboard System
39
To reset the lamp timer
1.
Press the power button
on the ECP or remote control twice to put the projector back into Standby
mode. The power button light on the ECP turns solid amber when the system is in Standby.
2.
Press and hold the
up
button on the remote control for approximately 10 seconds. When the projector
beeps, press and hold the
down
button on the remote control for approximately 10 seconds. The lamp
timer clears after another beep.
3.
Press the power button on the ECP or the remote control to start up the system. The power button light on
the ECP turns solid green when the system starts.
4.
To confirm that the lamp timer has been reset, press the
MENU
button on the remote control. Scroll to the
Status Display
menu heading, and then confirm that
0 h
appears in the
Lamp timer
field. Your lamp reset
count has increased by one.
5.
Wait five minutes for the projector lamp to warm up.
6.
After confirming that the lamp timer has been reset, put the system in Standby by pressing the power button
twice on the ECP or the remote control. The power button light on the ECP turns solid amber when the
system is in Standby.
7.
When you are ready to use the system, press the power button on the ECP to start up the system.
Содержание SmartBoard 600i2
Страница 1: ...Configuration and User s Guide SMART Board 600i2 Interactive Whiteboard System...
Страница 8: ...vi Important Information 99 00850 21 B0...
Страница 16: ...6 About Your 600i2 Interactive Whiteboard System 99 00850 21 B0...
Страница 30: ...20 Before Installing Your 600i2 Interactive Whiteboard System 99 00850 21 B0...
Страница 50: ...40 Maintaining Your 600i2 Interactive Whiteboard System 99 00850 21 B0...
Страница 64: ...54 Remote Management of Your 600i2 Interactive Whiteboard System 99 00850 21 B0...
Страница 72: ...62 Index 99 00850 21 B0...
Страница 73: ......