Protection
Protection Module Configuration with IMx-M Manager
2 - 104
SKF Multilog On-Line System IMx-M
User Manual
Use DNS
supports domain name server implementation by
allowing the server's primary name and the secondary name. The
secondary name is optional.
Figure 2 - 81.
Using DNS with Hardware Switches to Assign the Slot IP Address.
Save as File
creates a Network configuration file, ready for USB download to the
condition monitoring module of this slot. The process of actually connecting to, and
downloading this file to the condition monitoring module is described in
. By default, the name of the network file will be "SysCfg_#.IMX"
where # is the device number of the slot.
Set Ethernet Factory Defaults
sets all the values back to the factory default values.
Important
–
Please consult the IT department or provider to ensure that
whatever port is selected and entered, all firewalls between the slot and the actual
service have this port opened for bidirectional data traffic.
Saving a Network Configuration
Once the network settings for the selected slot have been entered, a network
configuration file (*.imx) can be created and saved, ready for the USB download to the
condition monitoring module.
To create a network configuration file of the selected slot, simply right-click on the slot
and select
Save Network Configuration File
or select
Save as File
when configuring
network settings as described above.