Protection
Modbus
2 - 182
SKF Multilog On-Line System IMx-M
User Manual
Exported (Read) Modbus Registers
IMx-M item
Register
number(1)
Function
Data type
Min and Max
Dig Ch 8 Status
89
"Digital Ch Status" Bit
Definition
RLM Slave 0
Relay Status
129
Relays 1 to 4
(6)
16-bit mask
-
RLM Slave 7
Relay Status
136
Relays 29 to 32
(6)
System
Status 2
257
See table
16-bit mask
-
Analog Ch 1
Sensor OK Max
Threshold
513
Analog Ch 1 Sensor
OK max threshold(5)
Signed 16 bits
-32 768 to
+32 767
Analog Ch 16
Sensor OK Max
Threshold
528
Analog Ch 16 Sensor
OK max threshold(5)
Analog Ch 1
Sensor OK Min
Threshold
561
Analog Ch 1 Sensor
OK min threshold(5)
Signed 16 bits
-32 768 to
+32 767
Analog Ch 16
Sensor OK Min
Threshold
576
Analog Ch 16 Sensor
OK min threshold(5)
Modbus L1
Statistics(2)
609
Number of Short
frame errors
Unsigned 16 bits
0 to 65 535(4)
610
Number of Long
frame errors
611
Number of CRC
errors
612
Number sent
613
Number received
614
Number of Rx timeout
errors
615
Number of Uart
errors