Installation Instructions Document No. 466-1574
19
Option 43: Pager Phone Number
Add enables pager phone number. Program the pager
phone number. The phone number can only call a
pager. Some pagers may require 3 or 4 additional
pauses be appended to the phone number.
Delete disables pager phone number. The phone num-
ber will not be called in an alarm situation.
Option 44: Pager Phone Mod 3
Add enables pager phone mod 3 sets the report content
and format the pager phone number uses. Use the fol-
lowing table to determine the value to enter.
Delete sets pager phone mod to 8.
Table 17 Pager Reporting Message
Option 45: Sensor Alarm Restoral
Add enables sensor alarm restoral. This sends a report
to the central station when a restoral sensor that is in
alarm is restored.
Delete disables sensor alarm restoral reports.
Option 46: Fire Shutdown - AVM*
Add enables fire shutdown - AVM. This option allows
the panel to turn off the sirens during a two way voice
session with the user and the central station. Beeps
will sound every 10 seconds while the sirens are off.
Delete disables fire shutdown - AVM. If this option is
turned off, the sirens will not shut off during a two
way voice session.
Option 47: AVM Mode*
Add enables AVM mode. This allows the central sta-
tion to hang up and call the panel back for a two way
voice session.
Delete disables AVM mode. When this option is off,
the two way session will start immediately.
Option 48: Panic Talk*
Add enables panic talk. This allows the central station
to listen and talk to the user during a silent alarm.
(Sensor type 02 or 03 or if the Panic Code was en-
tered).
Delete disables panic talk. When this option is turned
off, the central station may only listen during a silent
alarm.
Option 49: Rechargeable Battery
Add enables the rechargeable battery to be used.
Delete enables the lithium battery to be used.
Option 50: RF Jam Detect
Add enables RF jam detect. This allows the Control
Panel to detect RF interference. The control panel will
call the Central Station if RF jam detect is on and the
panel receives a constant 319.5 MHz signal.
Option 50 Detected is the status message for this op-
tion.
Delete disables RF jam detect. When this option is
turned off, the Control Panel is unable to detect RF in-
terference.
Table 16 Pager Phone Mod Format
Enter
#
Reports
Format
8
Latchkey, No Activity, Phone Test,
Openings, Closings, Fail to Open/
Close, AC Power Restorals/Failures
Pager
9
The same as Phone Mod 8 plus Alarms
Pager
Use the following table to determine what the numer-
ic message is reporting.
Reports
Numeric Message
Phone Test
-101 -101
AC Power Restoral
-102 -102
AC Power Failure
-103 -103
Latchkey
-104 -104
No Activity
-105 -105
Panic Code
-106 -106
Emergency
-107 -107
Intrusion
-108 -108
Fire
-109 -109
Openings
-110 -110
Closings
-111 -111
Fail to Open
-112 -112
Fail to Close
-113 -113
* = Not Available with Basic Model