Installation Instructions Document No. 466-1574
.
20
Option 51: 24 Hour Battery Test
Add sets battery test period to 24 hours. This feature
is only useful when using a non-rechargeable Ultra-
Life 9V lithium battery because it extends battery life.
Delete sets battery test period to 4 hours.
Option 52: High Level Status
Add sets status beeps and arming level beeps to high
volume.
Delete sets status beeps and arming level beeps to low
volume.
Option 53: Hardwire Siren Supervision
Add turns hardwire siren supervision on. Turn this op-
tion on if installing a hardwire siren and supervision
is desired.
See the “Wiring the Control Panel” on page 21 for the
correct EOL resistor connection.
Delete turns hardwire supervision off and is the ap-
propriate setting if hardwire sirens are not being con-
nected.
Reset Memory to the Factory Defaults
If it becomes necessary to set all programming back
to the factory defaults, do the following:
1. Open the Control Panel cover.
2. Unplug the transformer and the battery.
3. Simultaneously press Cancel, Clock Set, and
Minutes.
4. Restore power to the panel with either the battery
or the transformer while pressing these three but-
tons.
5. Plug in the transformer or connect the battery.
NOTE: If Phone Lock is on, options 04, 05, 06, 08, 09,
12, and 13 will not reset to their defaults.