Installation Instructions Document No. 466-1574
17
Delete disables the Control Panel’s piezo from sound-
ing alarms. Alarms will not sound from the Control
Panel.
For UL listed systems, at least one listed external au-
dible signal device shall be used if the external piezo
is disabled.
Option 30: Panic Alarms
Add enables all panic alarms (intrusion, auxiliary, and
fire) initiated from the Control Panel. Use the decal
included with the Control Panel if this option is on.
Delete disables intrusion, auxiliary, and fire panic
buttons on the control panel. The emergency button
on the control panel is always active.
Option 31: Day of Week
Add will program the day of week based on a pro-
grammed number. The day of week may be viewed in
the event buffer using ToolBox.
Delete sets day of week to 0.
Option 32: 300 Baud
Add enables 300 baud communication. Enable this
option for faster communication
Delete enables 110 baud communications
Option 33: 2-Way Voice*
Add enables 2-way voice communications between
the security system site and a monitoring station. 2-
way voice is also available to the owner if Ring/Hang/
Ring (option 27) is on.
Delete disables 2-way voice.
Do the following to conduct an audio session:
1. After the panel has completed reporting the
alarm, pick up the CS phone.
2. Press the * button on the phone to start the audio
session.
3. Press 1 or 0 to speak and 3 or 6 to listen.
4. Press 99 to terminate the session.
Note: To conduct an audio session using remote phone ac-
cess see Table 13 on page 14.
Option 34: Fail to Open
Add enables fail to open. If the panel has not been dis-
armed by the programmed opening time, the panel
will call in a fail to open alarm to the Central Station
and/or a pager.
Delete disables fail to open.
Option 35: Fail to Close
Add enables fail to close. If the panel has not been
armed by the programmed opening time, the panel
will call in a fail to close alarm to the Central Station
and/or a pager.
Delete disables fail to close.
Option 36: Sensor Activated Light Lockout Start
Time*
Add enables sensor activated light lockout start time.
The panel will not turn on a light between the pro-
grammed start time (option 36) and the programmed
stop time (option 37), even if sensor activated lights
are on. Both options must be programmed for this
option to work correctly.
Delete disables sensor activated light lockout start
time. The panel will turn on a light activated by a sen-
sor at all times if sensor activated lights are enabled.
Table 14 Day of Week by Number
0
Sunday
1
Monday
2
Tuesday
3
Wednesday
4
Thursday
5
Friday
6
Saturday
Table 15 Audio Verification Set
Phone
Button(s)
Audio Verification System
1
Speak
3 or 6
Listen
7
Extend session for 90 more seconds
88
Terminates session with call back (the
panel will answer on the first ring if
called within 5 minutes)
99
Terminates session with no call back
* = Not Available with Basic Model