Installation Instructions Document No. 466-1574
.
18
Option 37: Sensor Activated Light Lockout Stop
Time*
Add enables sensor activated light lockout stop time.
The panel will not turn on a light, between the pro-
grammed start time (option 36) and the programmed
stop time (option 37), even if sensor activated lights
are on. Both options must be programmed for this
option to work correctly.
Delete disables sensor activated light lockout stop
time. The panel will turn on a light activated by a sen-
sor at all times if sensor activated lights are enabled.
Option 38: Auto Arm
Add enables auto arm. Any sensor that requires resto-
ral and is open when the panel is armed will automat-
ically be bypassed when the panel is done protesting.
The panel will protest for 4 minutes, then auto arm.
Pressing the ARM Doors & Windows button a second
time will stop the control panel protest and auto arm
the system. Pressing this button a third time will arm
with no entry delay. The panel will go into alarm if an
instant alarm sensor is opened during an exit delay. A
sensor learned as type 26 can never be bypassed.
Delete disables auto arm. Any sensor that requires
restoral and is open when the exit delay expires will
automatically be bypassed. Beeps indicating the arm-
ing level will sound four times when the control panel
is armed and one time when the exit delay ends. The
panel will go into alarm if an instant alarm sensor is
opened during an exit delay. A sensor learned as type
26 can never be bypassed.
Option 39: Siren Time Out
Add programs siren time out from 1 to 30 minutes.
The default siren time out is 4 minutes.
Delete siren never time out.
Option 40: Trouble Beeps
Add enables trouble beeps. If there is a trouble condi-
tion, six beeps will sound every minute. If the panel is
armed, disarmed, or status is pressed, the trouble
beeps will stop and then resume 4 hours later.
Trouble beeps will be heard if:
•
There is AC power failure.
•
The CPU battery is low.
•
There is a sensor failure.
•
There is sensor trouble.
•
There is a fail to communicate problem.
•
The no activity timer has timed out. Trouble
beeps will continue for 5 minutes and if the panel
does not see activity, the trouble beeps will stop
and the panel will call the CS to report the no
activity.
Delete disables trouble beeps, so that if a problem oc-
curs the control panel will not notify the owner with
trouble beeps.
Option 41: Chime Voice
The panel has two chime modes which may be en-
abled by pressing the appropriate button on the panel.
CHIME Doors
Chime doors is a chime sound (two beeps) that will be
emitted from the interior siren output, the panel siren,
SWS, and the X-10 powerhorn siren (if set to unit #9)
when a door/window sensor which is type 10 or 13 is
activated. If there are no sensors learned as type 10 or
13, this function will not be available. The panel will
announce which sensor was tripped if chime voice is
on and the sensor was opened while the panel is dis-
armed.
CHIME Special Motion*
Chime special motion is a chime sound (three beeps)
that will be emitted from interior siren output, the
panel siren, SWS, and the X-10 powerhorn siren (if
set to unit #9) when a chime sensor that is type 25 is
activated (the alarm state is sent to the panel). If there
are no sensors learned as type 25, this function will
not be available. The panel will announce which sen-
sor was tripped if chime voice is on and the sensor
was opened while the panel is disarmed.
Add enables chime voice. The panel will announce
which chime sensor has been tripped if the chime fea-
ture is enabled.
Delete disables chime voice. The panel will not an-
nounce which chime sensor has been tripped even if
the chime feature is enabled.
Option 42: Speaker Level*
Add sets speaker level to the high voice level.
Delete sets the speaker level to the low voice level.
* = Not Available with Basic Model