Table 18
Programmable Options
Op
-
ti
on #
Function
Default
Delete
Range
Who Can
Change:
U1 - Utility
Access Code 1;
U2 - Utility
Access Code 2;
M - Master;
Installer
Settings
01
Panel Piezo Beeps
On
Off
On/Off
U1 U2 M
02
Panel Voice
On
Off
On/Off
U1 U2 M
03
Latchkey Option
Off
Off
12:00 AM-
11:59 PM
U1 U2 M
04
Primary Phone Number
None
None
22 digits
U1
05
Secondary Phone Number
None
None
22 digits
U1
06
Downloader Phone Number
None
None
22 digits
U1
07
Account Number
00000
00000
00000-
99999
U1 U2
08
Phone Lock
Off
Off
On/Off
U1
09
Downloader Code
12345
12345
00000-
99999
U1
10
Entry Delay
030 sec
005 sec
005-120 sec
U1 U2
11
Exit Delay
030 sec
005 sec
005-120 sec
U1 U2
12
Phone Mod 1
0
0
0-3
U1
13
Phone Mod 2
0
0
0-9
U1
14
DTMF
On
Pulse
On/Off
U1 U2
15
No Activity Report
Off
Off
02-24 hrs
U1 U2
16
Auto Phone Test (Must be enabled for UL
Listed systems)
Off
Off
001-254
days
U1 U2
17
Dialer Delay
Off
Off
001-120 sec
U1 U2
18
Alarm Cancel Report
Off
Off
001-255 min
U1 U2
19
Supervisory Time (SUPSYNC)
12 hrs
02 hrs
02-24 hrs
U1 U2
20
Manual Phone Test
On
Off
On/Off
U1 U2
21
Opening Reports
Off
Off
On/Off
U1 U2
22
Closing Reports
Off
Off
On/Off
U1 U2
23
Force Armed Report
Off
Off
On/Off
U1 U2
24
AC Power Failure Report (Must be enabled
for UL Listed systems)
Off
Off
On/Off
U1 U2
25
CPU Low Battery Report (Must be enabled
for UL Listed systems)
On
Off
On/Off
U1 U2
26
Fail to Communicate (Must be enabled for
UL Listed systems)
On
Off
On/Off
U1 U2
27
Ring/Hang/Ring
1
Off
1-4