Installation Instructions Document No. 466-1574
.
32
•
Screwdriver
To mount the panel:
1. Choose a spot within a few feet of an electrical
outlet (the outlet should not be controlled by a
wall switch) and also within reach of a telephone
jack. The Control Panel can be placed on a desk,
tabletop, or it can be wall mounted.
2. Open the Control Panel cover and position on the
wall.
3. Mark the screw hole locations with a pencil.
4. Start holes with the tip of the screwdriver or a
nail.
5. Tap the wall anchors provided into the holes.
6. Insert the screws and partially tighten with the
screwdriver.
7. Hang the Control Panel on the screws and tighten
securely.
8. Remove the center screw from the outlet cover
plate.
9. Position the transformer so that its screw hole is
aligned with the screw hole on the outlet cover
plate. Then plug the transformer into the outlet.
10. Replace the screw, and use it to secure the trans-
former to the outlet cover plate. Tighten the
screw firmly with your screwdriver.
Sensor Installation
Use the installation instructions included with each
sensor or if installing SAW sensors use document
466-1622, Booklet of Installation Instructions, at-
tached to the back of this manual, for SAW Sensors.
Testing the Control Panel
Test the Control Panel by pressing the buttons as de-
scribed below:
•
ARM Doors & Windows-The Control Panel
arms Doors & Windows. Press twice to eliminate
the preprogrammed entry delay. The button will
blink when No Entry Delay is on.
•
ARM Motion Sensors-The Control Panel will
arm Motion Sensors. Press twice to turn Latch-
key on. The button blinks when Latchkey is on.
•
DISARM -The Control Panel will disarm Doors,
Windows, and Motion Sensors when also enter-
ing the appropriate access code.
•
SYSTEM STATUS-Press to determine system
status and system time.
•
CHIME Doors-Press to enable two beeps which
will sound from the interior siren output, the
panel siren, SWS, and the X-10 powerhorn siren
(if set to unit number 9) when a protected door or
window, that is programmed as sensor type 10 or
13, is opened.
•
CHIME Special Motion- Press to enable three
beeps which will sound from the interior siren
output, the panel siren, SWS, and the X-10 pow-
erhorn siren (if set to unit number 9) when a
Motion Sensor, that is programmed as sensor
type 25, is activated. If there are no sensors
learned as type 25, this function will not be avail-
able. The control panel will also announce which
sensor was tripped if chime voice (option 41) is
on.
•
LIGHTS Time Activated-Press to enable system
controlled lights to turn on/off at a scheduled
time.
•
LIGHTS Sensor Activated-Press to enable sys-
tem controlled lights to turn on for 4 minutes
when a specific sensor is tripped.
•
EMERGENCY-Press and hold or press twice
quickly to activate a non-medical emergency
alarm.
Testing the System
This section describes how to perform the following
test procedures:
• Testing sensors
• Testing phone communication
• Testing central station communications
• Testing the X-10 Lamp Modules
You should test the system after installing, after ser-
vicing, and after adding or removing devices from the
system.
Testing Sensors
We recommend that you test the sensors after all pro-