156
157
Advanced operations
Advanced operations
7
>>MISC SETTINGS
2
CARRIAGE SPEED
Press the
OK
key.
8
2
SLOW
>>>CARRIAGE SPEED
2
NORMAL
,
Press the
Up
and
Down
keys to select
NORMAL
or
SLOW
.
9
>>>CARRIAGE SPEED
2
*SLOW
Press the
OK
key.
SLOW is set in the example on the left.
Print speed
The print speed depends on the print mode and the carriage speed. Print speeds are shown in the table below.
The real print speed may be slower than the indicated values depending on factors such as the media width.
Print speeds of the IP-6620 *1
Print mode
Carriage speed
NORMAL
SLOW
DRAFT
66.5 m
2
/h
40.6 m
2
/h
FAST PRODUCTION
49.7 m
2
/h
30.4 m2/h
PRODUCTION
33.1 m
2
/h
20.2 m
2
/h
PRODUCTION / HIGH DENSITY
STANDARD
23.9 m
2
/h
14.2 m
2
/h
STANDARD / HIGH DENSITY
QUALITY
16.0 m
2
/h
9.5 m
2
/h
QUALITY / HIGH DENSITY
HIGH QUALITY
9.2 m
2
/h
5.4 m
2
/h
HIGH QUALITY / HIGH DENSITY
MAX QUALITY
6.0 m
2
/h
3.5 m
2
/h
MAX QUALITY / HIGH DENSITY
*1 The indicated speed values are when printing full width on a media of 1626 mm (64 inches) in width.
Adjust the heaters temperatures
Each heater initial value is set in the media preset menu. These values are automatically set for the heaters
temperatures.
Therefore, normally the heater control menu is not required.
The heater control menu is used to:
- Complete the temperature fine adjustment during the print operation; or
- Confirm the current heater temperature
Procedure to set the heaters temperatures
(1) The heaters are in standby at the initial temperature
registered with the media used.
>>AFTERHEATER T
*50
→
50ºC
◎
>>PRINTHEATER T
*40
→
40ºC
◎
>>PREHEATER T
*45
→
45ºC
◎
When a media type is selected after installing the media, initial
temperature values of each heater for the selected media type are
displayed on the menu.
(2) Heating starts after receiving the data from the RIP
software.
RIP data
When the heaters temperatures are set with the print and job data
from the RIP software, the temperatures on the heater control
menu are overwritten by the temperatures from the RIP.
To use the initial temperatures set on the operation panel
rather than the temperature set with the RIP, set HEATER
PRIORITY in the media preset menu to PANEL SETTING.
(3) When the heaters temperatures have almost reached
the set temperatures, the print operation starts.
When the current temperatures of the afterheater, printheater,
and preheater reach a temperature of 1ºC lower than the set
temperature, the printer starts printing.
The heaters maximum set temperatures are as follows.
Afterheater: 55ºC, Printheater: 55ºC, Preheater: 55ºC
Even after the print is completed, the temperatures
changed during this procedure remain as the heaters setup
temperatures, until the media is installed again or the printer
is turned off.
However, the heater temperature settings in the media
preset menu are not changed.
(4) Changing the heaters temperatures during the print
operation.
■■
45 50
45ºC
Aft 40 +50
45Pre
HEATER
During the print operation the heaters temperatures may be
changed by specifying set temperatures in the heater control
menu.
Be
fo
re
p
rin
tin
g
Lo
adi
ng
the
m
edi
a
A
dj
us
tm
ent
M
ai
nt
enan
ce
A
dv
an
ce
d
op
er
ati
on
s
Trou
ble
sh
oo
tin
g
M
enu
tr
ee
Ap
pe
nd
ix
Содержание IP-6620