Configuration
59
Siemens Building Technologies
Fire Safety & Security Products
03.2007
NOTE
For the
Record
action, the camera you select should be set to the Event or Time & Event recording
mode in the
Record Schedule
setup screen.
2.
Highlight the box under the
Alarm-Out
heading and press the
button.
Î
A list of Alarm Outputs appears.
You can associate as many Alarm-Outs with the Text Input as you wish.
When the DVR detects text input, it triggers output signals on all the
associated Alarm-Out connectors. You can also have the DVR’s internal
buzzer sound if text input is detected.
NOTE
For the
Alarm-Out
action, the alarm output and beep you select should be set to the Event mode in
the
Alarm-Out
setup screen (
Schedule
tab).
3.
Highlight the box under the
Notify
and press the button.
You can toggle the entire list On and Off by highlighting
Notification
and
pressing the button. You can toggle the individual items On and Off by
highlighting that item and pressing the button.
4.
Highlight
OK
and press the button to accept your changes.
NOTE
For the
Notify
action, the notify item you select should be enabled in the
Notification
setup screen
and the DVR should be registered in the RAS (Remote Administration System).
Fig. 59
Text-In Actions 2 screen
Actions 2
1.
Highlight the desired box under the
PTZ
heading, and press the button.
Î
A list of PTZ presets appear.
2.
Select the preset positions for each PTZ camera, where you want PTZ
cameras to move to when the DVR detects text input.