Configuration
34
Siemens Building Technologies
Fire Safety & Security Products
03.2007
3.
Highlight the slide bar beside
Auto Deletion
, and use the Left and Right
arrow buttons to adjust the length of time recorded data will be kept from 1 to
99 days.
Î
The DVR automatically deletes video recorded earlier than the user-defined
period under three conditions: at midnight, whenever the system reboots or
whenever the user changes the
Auto Deletion
settings. Selecting "Never" will
disable the Auto Deletion function.
Highlighting
Use Panic Recording
and pressing the
button toggles
between On and Off.
4.
Highlight the
Panic Recording
–
Duration
box and set the duration of panic
recording.
Î
Panic recording will stop automatically after the preset duration as long as the
Panic button is not pressed to stop the panic recording. You can set the dwell
from 5 minutes to 1 hour. Select "No Limit" if you want to stop panic recording
manually.
Highlighting the
Panic Recording – ips
box and pressing the button
allows you to set the images per second for Panic recording. You can select
from 0.10 to 25.0 (30.0 for NTSC) images per second.
Highlighting the
Panic Recording – Quality
box and pressing the
button
allows you to set the recorded image quality for Panic recording. You can
select from: Very High, High, Standard and Low.
Î
You can save your
Record
settings by highlighting
Save
and pressing the
button.
Î
Selecting
Cancel
exits the screen without saving the changes.