Appendix
A.9 Information List
SIPROTEC, 7SJ62/64, Manual
C53000-G1140-C207-2, Release date 01.2008
678
7560
67N-1 InRush picked up (67N-1
InRushPU)
50/51 Overcur.
OUT
*
On
Off
*
LED
BO
60
85
2
Yes
7561
67-TOC InRush picked up (67-
TOC InRushPU)
50/51 Overcur.
OUT
*
On
Off
*
LED
BO
60
86
2
Yes
7562
67N-TOC InRush picked up
(67N-TOCInRushPU)
50/51 Overcur.
OUT
*
On
Off
*
LED
BO
60
87
2
Yes
7563
>BLOCK InRush (>BLOCK
InRush)
50/51 Overcur.
SP
*
*
*
LED BI
BO
7564
Ground InRush picked up (Gnd
InRush PU)
50/51 Overcur.
OUT
*
On
Off
*
LED
BO
60
88
2
Yes
7565
Phase A InRush picked up (Ia
InRush PU)
50/51 Overcur.
OUT
*
On
Off
*
LED
BO
60
89
2
Yes
7566
Phase B InRush picked up (Ib
InRush PU)
50/51 Overcur.
OUT
*
On
Off
*
LED
BO
60
90
2
Yes
7567
Phase C InRush picked up (Ic
InRush PU)
50/51 Overcur.
OUT
*
On
Off
*
LED
BO
60
91
2
Yes
10020
>BLOCK Load Jam Protection
(>BLOCK Jam Prot)
48/66 Motorprot
SP
On
Off
LED BI
BO
10021
Load Jam Protection is
BLOCKED (JAM PROT.BLOCK.)
48/66 Motorprot
OUT
On
Off
LED
BO
10022
Load Jam Protection is OFF
(JAM PROT.OFF)
48/66 Motorprot
OUT
On
Off
LED
BO
10023
Load Jam Protection is ACTIVE
(JAM PROT.ACTIVE)
48/66 Motorprot
OUT
On
Off
LED
BO
10024
Load Jam Protection alarm (Load
Jam alarm)
48/66 Motorprot
OUT
On
Off
*
LED
BO
10025
Load Jam Protection picked up
(Load Jam pickup)
48/66 Motorprot
OUT
On
Off
*
LED
BO
10026
Load Jam Protection TRIP (Load
Jam TRIP)
48/66 Motorprot
OUT
On
Off
*
LED
BO
10027
Startup Duration 1
(StartDuration1)
Mot.Statistics
VI
10028
Startup Current 1
(StartupCurrent1)
Mot.Statistics
VI
10029
Startup Voltage 1
(StartupVoltage1)
Mot.Statistics
VI
10030
Total Number of Motor Starts
(Nr.of Mot.Start)
Mot.Statistics
VI
10031
Total Motor Running Time (Motor
Run.Time)
Mot.Statistics
VI
10032
Total Motor Stopped Time (Motor
Stop.Time)
Mot.Statistics
VI
10033
Motor Percent Running Time
(Perc.Run.Time)
Mot.Statistics
VI
10034
50-3 BLOCKED (50-3
BLOCKED)
50/51 Overcur.
OUT
On
Off
On
Off
*
LED
BO
10035
50N-3 BLOCKED (50N-3
BLOCKED)
50/51 Overcur.
OUT
On
Off
On
Off
*
LED
BO
10037
Startup Duration 2
(StartDuration2)
Mot.Statistics
VI
10038
Startup Current 2
(StartupCurrent2)
Mot.Statistics
VI
10039
Startup Voltage 2
(StartupVoltage2)
Mot.Statistics
VI
10040
Startup Duration 3
(StartDuration3)
Mot.Statistics
VI
No.
Description
Function
Type
of In-
for-
matio
n
Log Buffers
Configurable in Matrix
IEC 60870-5-103
Ev
ent Log
O
N
/O
FF
T
rip (
F
a
u
lt)
Log ON
/O
FF
G
round
Fault Log ON/
O
FF
M
a
rk
e
d
i
n
O
s
ci
ll.
Re
c
o
rd
LED
B
ina
ry
I
n
pu
t
Function
Key
Rela