Appendix
A.1 Ordering Information and Accessories
SIPROTEC, 7SJ62/64, Manual
C53000-G1140-C207-2, Release date 01.2008
550
Functions
Pos. 14
and 15
Designation
ANSI No.
Description
Basic Elements (included in all ver-
sions)
—
Control
50/51
Time overcurrent protection phase 50-1, 50-2, 50-3, 51
50N/51N
Time overcurrent protection ground
50N-1, 50N-2, 50N-3, 51N
50N/51N
Insensitive time overcurrent protection ground via the in-
sensitive DGFD function: 50Ns-1, 50Ns-2, 51Ns
50/50N
Flexible protection functions (parameters from current):
additive overcurrent time protection 50-4
51V
Voltage-controlled inverse-time overcurrent protection
49
Overload protection (with 2 time constants)
46
Negative sequence protection
37
Undercurrent monitoring
47
Phase rotation
59N/64
Displacement voltage
50BF
Circuit breaker failure protection
74TC
Trip circuit monitoring
—
Cold-load pickup (dynamic setting changes) 50c, 51c,
50Nc, 51Nc, 67c, 67Nc
—
Inrush restraint
86
Lock out
V, f. P 27/59
81O/U
27/47/59(N)
/32/55/81R
Under/Overvoltage 59-1, 59-2, 27-1, 27-2
Under/Overfrequency
Flexible protection functions (parameters from current
and voltage): Voltage/power/power factor/frequency-
change protection
F E
IEF
V, f, P 27/59
81O/U
—
27/47/59(N)
/32/55/81R
Under/Overvoltage 59-1, 59-2, 27-1, 27-2
Under/Overfrequency
Intermittent ground fault
Flexible protection functions (parameters from current
and voltage): Voltage/power/power factor/frequency-
change protection
P E
Dir
67/67N
Directional overcurrent protection
F C
Dir
V, f, P 67/67N
27/59
81O/U
27/47/59(N)
/32/55/81R
Directional overcurrent protection
Under/Overvoltage 59-1, 59-2, 27-1, 27-2
Under/Overfrequency
Flexible protection functions (parameters from current
and voltage): Voltage/power/power factor/frequency-
change protection
F G
Dir
IEF
67/67N
—
Directional overcurrent protection
Intermittent ground fault
P C
DGFD
Dir
67/67N
67Ns
87N
Directional overcurrent protection
Directional sensitive ground fault detection
High-impedance ground fault differential protection
F D
DGFD
Dir
V, f, P 67Ns
87N
27/59
81U/O
27/47/59(N)
/32/55/81R
Sensitive ground fault detection
High-impedance ground fault protection
High-impedance ground fault protection
Under/Overfrequency
Flexible protection functions (parameters from current
and voltage): Voltage, power, power factor, frequency
change protection