8.13
Torque Current Regulator
The torque current regulator generates the motor’s Q-axis motor voltage. The torque producing
motor current reference (I
qs,ref
) is generated from the output of the frequency regulator. The
torque producing current feedback (I
qs
) comes from motor current D-Q converter. The torque
current regulator is evaluated at the inner current loop update rate. This regulator is the
innermost, i.e. fastest, control loop in the control, operating at the sampling rate of the system.
This is typically 3 to 6 kHz or approximately 9 kHz for high speed motors.
Note
The drive will switch to a higher sampling rate for high speed motors when either of two things
occur: if the motor rated frequency is set to 240 Hz or above, or if the SOP flag
"HighSpeedInterruptEnable_O" is set true.
To run at the higher sampling rate, the high speed hardware integrator must also be enabled.
The high speed hardware integrator is automatically enabled when the higher sampling rate is
enabled.
Advanced Operating Functions
8.13 Torque Current Regulator
Control Manual
Operating Manual, A5E50491925A
253
Содержание SINAMICS PERFECT HARMONY GH180
Страница 2: ......
Страница 22: ...Table of contents NXGPro Control Manual 20 Operating Manual A5E50491925A ...
Страница 24: ...Security NXGPro Control Manual 22 Operating Manual A5E50491925A ...
Страница 504: ...NEMA Table NXGPro Control Manual 502 Operating Manual A5E50491925A ...
Страница 516: ...List of abbreviations C 1 Symbols and Abbreviations NXGPro Control Manual 514 Operating Manual A5E50491925A ...
Страница 517: ...Index D NXGPro Control Manual Operating Manual A5E50491925A 515 ...
Страница 518: ...Index NXGPro Control Manual 516 Operating Manual A5E50491925A ...
Страница 530: ...Glossary NXGPro Control Manual 528 Operating Manual A5E50491925A ...
Страница 537: ......
Страница 538: ... XUWKHU QIRUPDWLRQ ZZZ VLHPHQV FRP GULYHV 6LHPHQV QGXVWU QF 3 XQW 9DOOH 5RDG 1HZ HQVLQJWRQ 3 8QLWHG 6WDWHV RI PHULFD ...