Alarms, faults and system messages
8.4 Alarms, alarm buffer, and alarm history
Converter with the control units CU240D-2
268
Operating Instructions, 04/2018, FW V4.9 SP10, A5E34262100B AF
I&M
data
Format
Explanation
Associated
parameters
Example for the
content
I&M3
Visible String [54]
Any comment
p8808[0 … 53] -
I&M4
Octet String[54]
Check signature to track chang-
es for Safety Integrated.
This value can be changed by
the user.
The test signature is reset to the
value generated by the machine
is p8805 = 0 is used.
p8809[0 … 53] Values of
r9781[0] and
r9782[0]
When requested, the inverter transfers its I&M data to a higher-level control or to a PC/PG
with installed STEP 7 or TIA Portal.
I&M0
Designation
Format
Example for the
content
Valid for
PROFINET
Valid for
PROFIBUS
Manufacturer-specific
u8[10]
00 … 00 hex
---
✓
MANUFACTURER_ID u16
42d hex
(=Siemens)
✓
✓
ORDER_ID
Visible String
[20]
„6SL3246-0BA22-
1FA0“
✓
✓
SERIAL_NUMBER
Visible String
[16]
„T-R32015957“
✓
✓
HARDWARE_REVISION
u16
0001 hex
✓
✓
SOFTWARE_REVISION
char, u8[3]
„V“ 04.70.19
✓
✓
REVISION_COUNTER
u16
0000 hex
✓
✓
PROFILE_ID
u16
3A00 hex
✓
✓
PROFILE_SPECIFIC_TYPE u16
0000 hex
✓
✓
IM_VERSION
u8[2]
01.02
✓
✓
IM_SUPPORTED
bit[16]
001E hex
✓
✓
8.4
Alarms, alarm buffer, and alarm history
Alarms
Alarms have the following properties:
●
Incoming alarms have no direct influence on the inverter.
●
Alarms disappear again when the cause is eliminated.