Installing and connecting the device
3.2 Mounting the device
SIMATIC IPC1047
30
Operating Instructions, 09/2018, A5E45118479-AA
3.1.3
Permitted mounting positions
Optional installation locations
The device can be mounted horizontally in control desks, switching cabinets and 19" rack
systems.
NOTICE
Operation in closed rooms
The device is approved for operation in closed rooms only. Pay attention to the ambient
and environmental conditions.
3.2
Mounting the device
3.2.1
Installation guidelines
WARNING
Danger, high voltage
A high voltage may be present in the switchgear cabinet and could cause a dangerous
electric shock.
It may result in death or serious physical injury.
Isolate the power supply to the switchgear cabinet before opening it. Ensure that the power
to the switchgear cabinet cannot be turned on accidentally.
NOTICE
Fire hazard
If you install the device in an unapproved mounting position or if you do not observe the
ambient conditions, the device can overheat. UL approval and conformity with the low-
voltage directive (EN 60950-1:2006 and DIN EN 60950-1:2006-11) become void.
Overheating can cause a fire. Proper functioning of the device is no longer guaranteed.
Before you install the device, note the following general installation information.
Note
The device meets the requirements for fire protection enclosures in accordance with
EN 60950-1. It can therefore be installed without an additional fire protection enclosure.