Configuring and Parameterizing the CP 440
5-10
Point-to-point connection CP 440 Installation and Parameter Assignment
A5E00057742-02
Data Flow Control
In the following table the parameters for data flow control are described. Data flow
control is only possible when “Full Duplex (RS 422) Four-Wire Mode Point to Point”
is set.
Table 5-7
Data Flow Control (ASCII Driver)
Parameter
Description
Value Range
Default Value
Data Flow Control
Defines the type of data flow
control to be used.
•
None
•
XON/XOFF
•
None
XON Code
1
Code for XON
•
7 data bits
2
:
0 to 7FH (hex)
•
8 data bits
2
:
0 to FFH (hex)
•
11 (DC1)
XOFF Code
1
Code for XOFF
•
7 data bits
2
:
0 to 7FH (hex)
•
8 data bits
2
:
0 to FFH (hex)
•
13 (DC3)
Wait for XON after
XOFF (Wait Time
for CTS=ON)
3
Period of time for which the CP440
waits for the XON code or for
CTS=“ON” of the communication
partner when sending.
20 to 65535 ms
in 10 ms increments
•
20000 ms
1
Only in the case of XON/XOFF data flow control
2
Depends on whether you parameterize 7 or 8 data bits for the character frame (see Table 5-6).
3
Only in the case of XON/XOFF data flow control
Further Information
You will find more information on data flow control with XON/XOFF in
Section 2.2.2.