Diagnostics with the CP 440
8-11
Point-to-point connection CP 440 Installation and Parameter Assignment
A5E00057742-02
Table 8-2
Event Classes and Event Numbers, continued
Event No.
Remedy
Event
(08)11H
Character frame error
Check the connecting cable of the
communication partner, or check whether
both devices have same setting for the
transmission rate, parity and number of stop
bits.
Correct fault by changing system setup or
line installation.
(08)12H
With ASCII driver only:
More characters were received after the
CP had sent XOFF or set CTS to OFF
Reparameterize the communication partner,
or deal with the data in the CP more quickly.
(08)14H
With ASCII driver only:
A message frame or several message
frames have got lost, because you have
been working without flow control.
Work with flow control as much as you can.
Use the entire receive buffer. Set the
“Reaction to CPU Stop” parameter in the
basic parameters to “Continue”.
(08)16H
The length of a received message frame
was longer than the maximum specified
length.
Correction required at the partner
Event class 11 (0B8H):
“Warnings”
Event No.
Event
Remedy
(0B)01H
Receive buffer more than 2/3 full
Call the receive block more often to avoid
the receive buffer overflowing.
Event class 128 (80H):
“Module error”
Event No.
Event
Remedy
(80)00H
Module firmware does not exist
Carry out a firmware update.