Connecting Cables
B-2
Point-to-point connection CP 440 Installation and Parameter Assignment
A5E00057742-02
B.1
X27 (RS 422/485) Interface of the CP 440
Pin Assignment
The table below shows the pin assignment for the 15-pin subminiature D female
connector in the front panel of the CP 440.
Table B-1
Pin Assignment for the 15-Pin Subminiature D Female Connector of the Integrated Interface
of the CP 440
Female Connector
on the
CP440-RS422/485*
Pin
Designatio
n
Input/Output
Meaning
1
–
–
–
2
T (A)–
Output
Transmitted data (four-wire operation)
3
–
–
–
15
14
8
7
6
4
R (A)/
T (A) –
Input
Input/Output
Received data (four-wire operation)
Received/transmitted data (two-wire
operation)
14
13
12
6
5
5
–
–
–
3
12
11
5
4
6
–
–
–
3
2
10
11
10
9
7
–
–
–
1
9
8
GND
–
Functional ground (floating)
9
T (B) +
Output
Transmitted data (four-wire operation)
10
–
–
–
11
R (B)/
T (B) +
Input
Input/Output
Received data (four-wire operation)
Received/transmitted data (two-wire
operation)
12
–
–
–
13
–
–
–
14
–
–
–
15
–
–
–
*
Front view