Approvals, certificates, standards
9.3 Product group XR-300M
SCALANCE X-300
242
Operating Instructions, 05/2016, A5E01113043-20
Table 9- 3
Overview of the approvals
Device
Variant
c-UL-us
Inf. Tech.
Eq.
c-UL-us
for Hazard-
ous Loca-
tions
1)
c-UL-us
Ind. Cont.
Eq.
FM
1)
C-TICK
CE
ATEX95
Zone 2
1)
XR324-
12M
2 x 24 VDC,
Data cable
outlet on
front
●
●
-
●
●
●
●
1 x 100 to
240 VAC,
Data cable
outlet on
front
-
-
●
-
●
●
-
2 x 24 VDC
Data cable
outlet at rear
●
●
-
●
●
●
●
1 x 100 to
240 VAC,
data cable
outlet at rear
-
-
●
-
●
●
-
1
For temperature information "T.." or the maximum ambient temperature "Ta:..", refer to the type plate.
9.3.6
XR-300M mechanical stability (in operation)
Device:
SCALANCE
(Variant)
IEC 60068-2-6 vibration
IEC 60068-2-27 shock
IEC 60068-2-6 vibration *)
10 – 58 Hz: 0.15 mm
58 – 500 Hz: 1 g
1 octave/min,
10 cycles
15 g, 11 ms duration
6 shocks per axis
5 – 8.51 Hz: 7 mm
8.51 – 500 Hz: 1 g
1 octave/min,
10 cycles
XR324-12M ( 2 x DC data cable outlet on
front)
●
●
●
XR324-12M (1 x 100...240 VAC, data cable
outlet on front)
●
●
●
XR324-12M ( 2 x 24 VDC data cable outlet
at rear)
●
●
●
XR324-12M (1 x 100 to 240 VAC, data cable
outlet at rear)
●
●
●
*) Note: When rack mounted with 4 securing points