Technical specifications
8.2 X-300 technical specifications
SCALANCE X-300
156
Operating Instructions, 05/2016, A5E01113043-20
Type
Installation
location
Without media
module
MM992-2CUC
MM992-2CU
MM991-2
MM991-2LD
MM991-2 (SC)
MM991-2LD (SC)
MM992-2
MM992-2LD
MM991-2LH+ (SC)
MM992-2LH
MM992-2LH+
MM992-2ELH
Media module
MM992-2SFP
with SFP trans-
ceiver
SFP991-1
SFP991-1LD
SFP992-1
SFP992-1LD
Media module
MM992-2SFP
with SFP trans-
ceiver
SFP991-1LH+
SFP992-1LH
SFP992-1LH+
SFP992-1ELH
XR-300M
EEC
Horizontal
-40 °C to +70 °C
Maximum 2
modules in slots 11
and 12:
-40 °C to +60 °C
With more than 2
modules or other
slot assignment:
-40 °C to +50 °C
-40 °C to +70 °C
SFP transceivers
of this group can
only be used in
conjunction with
media modules
MM992-2CUC
and
MM992-2CU.
When using
other modules:
-40 °C to +60 °C
Maximum 2
modules in slots
11 and 12:
-40 °C to +60 °C
With more than 2
modules or other
slot assignment:
-40 °C to +50 °C
Vertical
-40 °C to +50 °C
The permitted operating temperature depends on how the mounting device was installed.
The installation is horizontal if the device labeling is from left to right. With a vertical
installation, the device labeling is rotated through 90°.
8.2
X-300 technical specifications
Note
Validity of the technical specifications
All the technical specifications described in this section that is not assigned to a specific
device variant, version or a media module, apply to all device variants/versions of the
product group.
Содержание SCALANCE X302-7EEC
Страница 14: ...Table of contents SCALANCE X 300 14 Operating Instructions 05 2016 A5E01113043 20 ...
Страница 38: ...Introduction 2 2 Product overview SCALANCE X 300 38 Operating Instructions 05 2016 A5E01113043 20 ...
Страница 320: ...Appendix A 6 Equipotential bonding SCALANCE X 300 320 Operating Instructions 05 2016 A5E01113043 20 ...