Approvals, certificates, standards
9.6 Product group X-300M PoE
SCALANCE X-300
Operating Instructions, 05/2016, A5E01113043-20
259
9.6.2
SCALANCE X-300 declaration of conformity
You will find the EC Declaration of Conformity for these products on the Internet at the
following address:
SCALANCE X-300 declaration of conformity
https://support.industry.siemens.com/cs/ww/en/ps/15296/cert
1.
Click on the entry "SCALANCE X-300 managed" in the navigation panel at the top edge
of the window and from the drop-down list that opens, select the entry for your product
group.
2.
Select the entry "Certificate" from the "Entry type"drop-down list.
Result: A list of the available certificates is displayed.
9.6.3
Overview of X-300M PoE approvals
Table 9- 6
Overview of the approvals
Device
c-UL-us
Inf. Tech. Eq.
c-UL-us
for Hazardous
Locations
1)
FM
1)
C-TICK
CE
ATEX95 Zone 2
1)
X308-2M PoE
●
●
●
●
●
●
1
For temperature information "T.." or the maximum ambient temperature "Ta:..", refer to the type plate.
Note
Shipbuilding approval
You will find shipbuilding approvals on the Internet on the pages of Siemens Industry
Automation Customer Support under the following entry ID:
Auto-Hotspot
"Entry list" tab > entry type "Certificates"
9.6.4
X-300M PoE mechanical stability in operation
The switch meets the following requirements for mechanical stability:
IEC 60068-2-6 (vibration)
●
Securing on a DIN rail
5 – 9 Hz: 3.5 mm
9 – 150 Hz: 1 g
1 octave/min, 20 sweeps