SCALANCE X-300
Operating Instructions, 05/2016, A5E01113043-20
155
Technical specifications
8
8.1
Overview of operating temperatures for SCALANCE X-300
Operating temperature depending on the media modules used
The information applies to media modules with product version 2 (PV2):
Type
Installation
location
Without media
module
MM992-2CUC
MM992-2CU
MM991-2
MM991-2LD
MM991-2 (SC)
MM991-2LD (SC)
MM992-2
MM992-2LD
MM991-2LH+ (SC)
MM992-2LH
MM992-2LH+
MM992-2ELH
Media module
MM992-2SFP
with SFP trans-
ceiver
SFP991-1
SFP991-1LD
SFP992-1
SFP992-1LD
Media module
MM992-2SFP
with SFP trans-
ceiver
SFP991-1LH+
SFP992-1LH
SFP992-1LH+
SFP992-1ELH
X-300M
Horizontal
-40 °C to +70 °C
-40 °C to +60 °C
Vertical
-40 °C to +50 °C
X-300M
PoE
Horizontal
-40 °C to +60 °C
-40 °C to +50 °C
-40 °C to +60 °C -40 °C to +50 °C
Vertical
-40 °C to +45 °C
XR-300M Horizontal
Not possible
(fully modular
device)
-40 °C to +70 °C
Maximum 2
modules in slots 11
and 12:
-40 °C to +60 °C
With more than 2
modules or other
slot assignment:
-40 °C to +50 °C
-40 °C to +60 °C
Maximum 2
modules in slots
11 and 12:
-40 °C to +60 °C
With more than 2
modules or other
slot assignment:
-40 °C to +50 °C
Vertical
Not possible
(fully modular
device)
-40 °C to +50 °C
XR-300M
PoE
Horizontal
-40 °C to +60 °C
Maximum 2
modules in slots 11
and 12:
-40 °C to +60 °C
With more than 2
modules or other
slot assignment:
-40 °C to +50 °C
-40 °C to +60 °C
Maximum 2
modules in slots
11 and 12:
-40 °C to +60 °C
With more than 2
modules or other
slot assignment:
-40 °C to +50 °C
Vertical
-40 °C to +50 °C
Содержание SCALANCE X302-7EEC
Страница 14: ...Table of contents SCALANCE X 300 14 Operating Instructions 05 2016 A5E01113043 20 ...
Страница 38: ...Introduction 2 2 Product overview SCALANCE X 300 38 Operating Instructions 05 2016 A5E01113043 20 ...
Страница 320: ...Appendix A 6 Equipotential bonding SCALANCE X 300 320 Operating Instructions 05 2016 A5E01113043 20 ...