Pin assignment for the RJ-45 connector of a PROFIBUS cable
If you use a PROFIBUS cable along with an IE FC RJ-45 plug 4x2, note the following:
RJ-45 connectors
PROFIBUS cable
Pin assignment
Color
Wire color
1
Yellow
Green
2
Orange
Red
3
White
--
6
Blue
--
Note
Using PROFIBUS standard cable GP
If you use a PROFIBUS standard cable GP, the wires must be stripped before they are
inserted in the FC connector.
Note
If you use cables with a length > 500 m, connection establishment can take up to 2 min.
Note
If you connect an MM992-2VD media module to existing PROFIBUS cabling, the same
requirements relating to shield contact and the lightning protection concept apply as for
PROFIBUS.
4.2.8.4
MM992-2M12 product characteristics
Possible attachments
The MM992-2M12 media module has the following:
●
2 x 10/100/1000 Mbps, GE M12 connector electrical
Image 4-28 MM992-2M12C [9922HA]
[Device labeling in square brackets]
Note
For connection to electrical networks note the information in Appendix (A.1, A.2 and A.3)