Introduction
2.1 Basics of Ethernet switching
SCALANCE X-300
26
Operating Instructions, 05/2016, A5E01113043-20
Technical options (network topologies)
The IE Switches X-300 simplify the expansion of a network regardless of the network
topology.
You can use an IE Switch X-300 in the following network topologies:
●
Linear structure
●
Star/tree structure
●
Ring with redundancy manager
The maximum cable length is 70 km for single mode gigabit transmission. A mixed topology
consisting of IE Switch X-300 devices and OSMs/ESMs is possible at the electrical ports. A
mixed topology consisting of IE Switch X-300 devices and an OSM via the optical ports is not
possible.
Using an IE Switch X-300 as the redundancy manager in a ring with redundancy manager
provides greater availability. If there is an interruption on the connection between these
switches, the IE Switch X-300 used as redundancy manager acts like a switch and in a very
short time creates a line from the ring. As a result, a functional, end-to-end structure is
restored. For information on this topic, refer to the Configuration Manual "SIMATIC NET -
Industrial Ethernet Switches SCALANCE X-300 SCALANCE X-400."