Approvals, certificates, standards
9.4 X-300EEC product group
SCALANCE X-300
248
Operating Instructions, 05/2016, A5E01113043-20
9.4.3
Overview of the approvals for the X-300EEC
Table 9- 4
Overview of the approvals
Device
Variant
c-UL-us
Inf. Tech.
Eq.
c-UL-us
for Hazard-
ous Loca-
tions
1)
c-UL-us
Ind. Cont.
Eq.
FM
1)
C-TICK
CE
ATEX95
Zone 2
1)
X302-
7EEC
X302-
2EEC
24 to 48
VDC
●
●
-
●
●
●
●
100...240
VAC /
60...250
VDC
-
-
●
-
●
●
-
1
For temperature information "T.." or the maximum ambient temperature "Ta:..", refer to the type plate.
9.4.4
X-300EEC mechanical stability (in operation)
All variants of the IE Switch SCALANCE X-300EEC meet the following requirements for
mechanical stability:
●
IEC 60068-2-6 (vibration)
5 – 9 Hz: 3.5 mm
9 – 150 Hz: 1 g
1 octave/min, 20 sweeps
●
IEC 60068-2-27 (shock)
15 g, 11 ms duration
6 shocks per axis
For further details, refer to the technical specifications.