Technical specifications
8.4 XR-300M technical specifications
SCALANCE X-300
176
Operating Instructions, 05/2016, A5E01113043-20
Table 8- 46 Reconfiguration times for redundancy mechanisms
Redundancy mechanism
Reconfiguration times
HRP
300 ms
Standby link
300 ms
MRP
200 ms
Mean time between failure (MTBF)
The values in the following table apply to the basic device without media modules.
Device version (power supply)
MTBF
1)
2 x 24 VDC
> 26 years
1 x 100 to 240 VAC
> 22 years
1)
These values apply at 40 °C.
In the calculation of the MTBF of a modular switch, the standard parts count applies; in other
words, the reciprocals of all component failure rates are added.
The reciprocal of this total id the MTBF of the entire assembly.
Table 8- 47 Full wire speed switching
Number of frames per second
At a frame length of
At 100 Mbps
At 1000 Mbps
148810
1488095
64 bytes
84459
844595
128 bytes
45290
452899
256 bytes
23496
234962
512 bytes
11973
119732
1024 bytes
9615
96154
1280 bytes
8127
81274
1518 bytes
Note
The following applies to IE Switches X-300:
The number of IE Switches X-300 connected in a line influences the frame delay time. When
a frame passes through the switch, this is delayed by the Store&Forward function of the
IE Switch X-300 by the following values:
•
at 64 bytes frame length: Delay of approx. 10 microseconds (at 100 Mbps)
•
at 1500 bytes frame length: Delay of approx. 130 microseconds
(at 100 Mbps)
This means, the more IE Switches X-300 a frame runs through, the higher the frame delay.