Technical specifications
8.3 X-300M technical specifications
SCALANCE X-300
Operating Instructions, 05/2016, A5E01113043-20
165
Table 8- 19 Installation options
Installation options
•
DIN rail
1)
•
S7-300 standard rail
•
Wall
1)
Note: When used in shipbuilding, installation on a 35 mm DIN rail is not permitted. In ships, the 35
mm DIN rail does not provide adequate support.
Table 8- 20 Permitted ambient conditions
Storage/transport temperature
-
40 °C to +85 ℃
Max. relative humidity in operation at 25 °C
<= 95% (no condensation)
Max. ambient temperature at operating altitude
2000 m or above:
-5 °C of the max. operating temperature
1)
3000 m or above:
-10 °C of the max. operating temperature
1)
1)
See table: "Operating temperature depending on the media modules used"
Table 8- 21 Operating temperature depending on the media modules used
Media module
Installation
direction
Operating temperature
1)
Without media module
Horizontal
-
40 °C to +70 ℃
Vertical
-40 °C
to +50 ℃
MM992-2CUC
MM992-2CUC (C)
MM992-2CU
MM992-2M12 (C)
MM992-2VD
MM991-2
MM991-2FM
MM991-2LD
MM991-2 (SC)
MM991-2LD (SC)
MM992-2
MM992-2 (C)
MM992-2LD
Horizontal
-
40 °C to +70 ℃
Vertical
-
40 °C to +50 ℃
MM991-2LH+ (SC)
MM992-2LH
MM992-2LH+
MM992-2ELH
Horizontal
-
40 °C to +70 ℃
Vertical
-
40 °C to +50 ℃
Media module MM992-2SFP
Horizontal
-
40 °C to +60 ℃