Data Exchange
6-7
MOBIC T8 for Windows CE 3.0
C79000-G8976-C190-02
Note
The MOBIC retains these settings following a reset. If, however, you run a cold
reset, the settings are reset to the standard serial port.
3. Establishing a Connection using Infrared
S
Align the infrared ports on both computers. Infrared links function best when
the distance between the two infrared ports is approximately 15 cm.
S
Click/tap Programs, Communication and PC Link one after the other on the
MOBIC.
To establish an infrared connection follow the steps as explained in the help
system of ActiveSync on your host PC (Start - > Programs - > Microsoft
ActiveSync - > Help - > Microsoft ActiveSync Help - > Index - > IR
Connections). The procedure is otherwise basically the same as establishing a
serial connection (see 6.2.2).
6.2.4
Establishing a Connection with a Host Computer via Ethernet
Before you establish a connection via Ethernet, you must first configure the
connection (see Section 6.3)
To establish a connection via Ethernet, follow the steps below:
1. As described above, set up a partnership via a serial connection.
2. Then disconnect the serial connection by removing the serial cable.
Содержание MOBIC T8 for Windows CE 3.0
Страница 5: ...i MOBIC T8 for Windows CE 3 0 C79000 G8976 C190 02 Preface ...
Страница 23: ...Overview 1 12 MOBIC T8 for Windows CE 3 0 C79000 G8976 C190 02 ...
Страница 105: ...Supplied Programs and Tools 7 18 MOBIC T8 for Windows CE 3 0 C79000 G8976 C190 02 ...
Страница 130: ...12 1 MOBIC T8 for Windows CE 3 0 C79000 G8976 C190 02 Certificates Directives and Declarations 12 ...
Страница 135: ...13 1 MOBIC T8 for Windows CE 3 0 C79000 G8976 C190 02 Frequently Asked Questions FAQs 13 ...
Страница 141: ...14 1 MOBIC T8 for Windows CE 3 0 C79000 G8976 C190 02 Technical Specifications 14 ...